Denis Cimaf DAF-180E: specs & which machines can run it
Forestry Mulcher rated for 50 GPM. Good fit on 2 of the 64 loaders we track.
Specs
- Type
- Forestry Mulchers
- Flow class
- not published
- Min flow
- 50 GPM
- Max flow
- not published
- Min pressure
- not published
- Max pressure
- 6000 PSI
- Min HP
- 125
- Max HP
- not published
- Width
- 74 in
- Weight
- 3300 lb
Maker lists required continuous flow (a minimum) and minimum HP; no maximum flow published.
Source: https://www.deniscimaf.com/msdenis/assets/specsheets/DAF-Spec-SheetNB.pdf (official)
Placeholder · affiliate link
Affiliate / “get a quote” link for Denis Cimaf DAF-180E goes here. No affiliate program is connected yet.
Placeholder · featured partner slot
Featured maker / dealer slot — Denis Cimaf dealers. Reserved for a future paid placement. No partner has been signed. This box is intentionally empty.
Verify with your dealer. Results come from published specs and our matching rules. They are not a guarantee. Coupler type, case-drain line, electrical connectors, auxiliary options, relief settings and model year all matter. Confirm with the dealer and the attachment maker before you buy or run anything.
Machines that can run the Denis Cimaf DAF-180E
2 good fit1 marginal61 won't run
- Good fitASV RT-135 (high flow) · details50 GPM meets the 50 GPM minimum required flow. 4060 PSI is within the head's pressure rating. 132 HP is within the head's horsepower range.
- Good fitASV RT-135 Forestry (high flow)50 GPM meets the 50 GPM minimum required flow. 4060 PSI is within the head's pressure rating. 132 HP is within the head's horsepower range.
- Marginal
- Won't runASV RT-50 (standard flow)13.3 GPM is well below the 50 GPM minimum. 3000 PSI is within the head's pressure rating. 53.8 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 1400 lb rated operating capacity.
- Won't runASV RT-65 (standard flow)21.4 GPM is well below the 50 GPM minimum. 3771 PSI is within the head's pressure rating. 67.1 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2000 lb rated operating capacity.
- Won't runASV RT-75 (standard flow)22.6 GPM is well below the 50 GPM minimum. 3300 PSI is within the head's pressure rating. 74 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2750 lb rated operating capacity.
- Won't runASV VT-100 (standard flow)23 GPM is well below the 50 GPM minimum. 3481 PSI is within the head's pressure rating. 103.5 HP is well below the 125 HP minimum.
- Won't runASV VT-75 (standard flow)21.4 GPM is well below the 50 GPM minimum. 71.5 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2300 lb rated operating capacity.
- Won't runASV VT-80 (standard flow)24.7 GPM is well below the 50 GPM minimum. 3771 PSI is within the head's pressure rating. 71.5 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2800 lb rated operating capacity.
- Won't runBobcat S450 (standard flow)16.7 GPM is well below the 50 GPM minimum. 3300 PSI is within the head's pressure rating. 49 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 1370 lb rated operating capacity.
- Won't runBobcat S590 (standard flow)17.1 GPM is well below the 50 GPM minimum. 3500 PSI is within the head's pressure rating. 68 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2000 lb rated operating capacity.
- Won't runBobcat S64-2 (standard flow)17.6 GPM is well below the 50 GPM minimum. 3500 PSI is within the head's pressure rating. 68 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2300 lb rated operating capacity.
- Won't runBobcat S650 (standard flow)23 GPM is well below the 50 GPM minimum. 3500 PSI is within the head's pressure rating. 74 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2690 lb rated operating capacity.
- Won't runBobcat S66-2 (standard flow)17.6 GPM is well below the 50 GPM minimum. 3500 PSI is within the head's pressure rating. 74 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2400 lb rated operating capacity.
- Won't runBobcat S70 (standard flow)8.9 GPM is well below the 50 GPM minimum. 2000 PSI is within the head's pressure rating. 23.5 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 760 lb rated operating capacity.
- Won't runBobcat S76-2 (standard flow)23.3 GPM is well below the 50 GPM minimum. 3500 PSI is within the head's pressure rating. 74 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2900 lb rated operating capacity.
- Won't runBobcat S770 (standard flow)23 GPM is well below the 50 GPM minimum. 3500 PSI is within the head's pressure rating. 92 HP is well below the 125 HP minimum.
- Won't runBobcat S86-2 (standard flow)23 GPM is well below the 50 GPM minimum. 4061 PSI is within the head's pressure rating. 115 HP is just under the 125 HP minimum.
- Won't runBobcat T450 (standard flow)16.7 GPM is well below the 50 GPM minimum. 3300 PSI is within the head's pressure rating. 55 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 1490 lb rated operating capacity.
- Won't runBobcat T595 (standard flow)17.1 GPM is well below the 50 GPM minimum. 3500 PSI is within the head's pressure rating. 70 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2100 lb rated operating capacity.
- Won't runBobcat T64-2 (standard flow)17.6 GPM is well below the 50 GPM minimum. 3500 PSI is within the head's pressure rating. 68 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2300 lb rated operating capacity.
- Won't runBobcat T650 (standard flow)23 GPM is well below the 50 GPM minimum. 3500 PSI is within the head's pressure rating. 74 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2500 lb rated operating capacity.
- Won't runBobcat T66-2 (standard flow)17.6 GPM is well below the 50 GPM minimum. 3500 PSI is within the head's pressure rating. 74 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2400 lb rated operating capacity.
- Won't runBobcat T76-2 (standard flow)23.3 GPM is well below the 50 GPM minimum. 3500 PSI is within the head's pressure rating. 74 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2900 lb rated operating capacity.
- Won't runBobcat T770 (standard flow)23 GPM is well below the 50 GPM minimum. 3500 PSI is within the head's pressure rating. 92 HP is well below the 125 HP minimum.
- Won't runBobcat T86-2 (standard flow)23 GPM is well below the 50 GPM minimum. 4061 PSI is within the head's pressure rating. 115 HP is just under the 125 HP minimum.
- Won't runCASE TR270B (standard flow)24.2 GPM is well below the 50 GPM minimum. 74 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 1890 lb rated operating capacity.
- Won't runCASE TR310B (standard flow)24.2 GPM is well below the 50 GPM minimum. 74 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2170 lb rated operating capacity.
- Won't runCASE TR340B (standard flow)24.2 GPM is well below the 50 GPM minimum. 90 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2380 lb rated operating capacity.
- Won't runCASE TV370B (standard flow)24.2 GPM is well below the 50 GPM minimum. 74 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2590 lb rated operating capacity.
- Won't runCASE TV450B (standard flow)24.2 GPM is well below the 50 GPM minimum. 90 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 3150 lb rated operating capacity.
- Won't runCASE TV620B (standard flow)24.2 GPM is well below the 50 GPM minimum. 114 HP is just under the 125 HP minimum.
- Won't runCat 239D3 (standard flow)18 GPM is well below the 50 GPM minimum. 3336 PSI is within the head's pressure rating. 67.1 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 1530 lb rated operating capacity.
- Won't runCat 249D3 (standard flow)18 GPM is well below the 50 GPM minimum. 3336 PSI is within the head's pressure rating. 67.1 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 1740 lb rated operating capacity.
- Won't runCat 259D3 (standard flow)20 GPM is well below the 50 GPM minimum. 3336 PSI is within the head's pressure rating. 74.3 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2010 lb rated operating capacity.
- Won't runCat 279D3 (standard flow)23 GPM is well below the 50 GPM minimum. 3336 PSI is within the head's pressure rating. 74.3 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2220 lb rated operating capacity.
- Won't runCat 289D3 (standard flow)23 GPM is well below the 50 GPM minimum. 3336 PSI is within the head's pressure rating. 74.3 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2890 lb rated operating capacity.
- Won't runCat 299D3 (standard flow)23 GPM is well below the 50 GPM minimum. 3335 PSI is within the head's pressure rating. 98 HP is well below the 125 HP minimum.
- Won't runCat 299D3 XE (standard flow)23 GPM is well below the 50 GPM minimum. 3335 PSI is within the head's pressure rating. 110 HP is well below the 125 HP minimum.
- Won't runJohn Deere 317G (standard flow)17 GPM is well below the 50 GPM minimum. 3450 PSI is within the head's pressure rating. 61 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2125 lb rated operating capacity.
- Won't runJohn Deere 325G (standard flow)21 GPM is well below the 50 GPM minimum. 3450 PSI is within the head's pressure rating. 70 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2590 lb rated operating capacity.
- Won't runJohn Deere 331G (standard flow)23.5 GPM is well below the 50 GPM minimum. 3450 PSI is within the head's pressure rating. 88.5 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 3100 lb rated operating capacity.
- Won't runJohn Deere 333G (standard flow)25 GPM is well below the 50 GPM minimum. 3450 PSI is within the head's pressure rating. 96.6 HP is well below the 125 HP minimum.
- Won't runKubota SVL65-2 (standard flow)17.4 GPM is well below the 50 GPM minimum. 3263 PSI is within the head's pressure rating. 68.4 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2100 lb rated operating capacity.
- Won't runKubota SVL75-3 (standard flow)19.2 GPM is well below the 50 GPM minimum. 3185 PSI is within the head's pressure rating. 71.6 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2490 lb rated operating capacity.
- Won't runKubota SVL97-2 (standard flow)23.1 GPM is well below the 50 GPM minimum. 3553 PSI is within the head's pressure rating. 96.4 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 3200 lb rated operating capacity.
- Won't runNew Holland C327 (standard flow)24.2 GPM is well below the 50 GPM minimum. 3046 PSI is within the head's pressure rating. 74 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2700 lb rated operating capacity.
- Won't runNew Holland C332 (standard flow)24.2 GPM is well below the 50 GPM minimum. 3046 PSI is within the head's pressure rating. 74 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 3200 lb rated operating capacity.
- Won't runNew Holland C334 (standard flow)24.2 GPM is well below the 50 GPM minimum. 3046 PSI is within the head's pressure rating. 90 HP is well below the 125 HP minimum.
- Won't runNew Holland C337 (standard flow)24.2 GPM is well below the 50 GPM minimum. 3046 PSI is within the head's pressure rating. 74 HP is well below the 125 HP minimum.
- Won't runNew Holland C345 (standard flow)24.2 GPM is well below the 50 GPM minimum. 3450 PSI is within the head's pressure rating. 90 HP is well below the 125 HP minimum.
- Won't runNew Holland C362 (standard flow)24.2 GPM is well below the 50 GPM minimum. 3450 PSI is within the head's pressure rating. 114 HP is just under the 125 HP minimum.
- Won't runNew Holland L316 (standard flow)18.4 GPM is well below the 50 GPM minimum. 3046 PSI is within the head's pressure rating. 60 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 1600 lb rated operating capacity.
- Won't runNew Holland L318 (standard flow)20.6 GPM is well below the 50 GPM minimum. 3046 PSI is within the head's pressure rating. 60 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 1800 lb rated operating capacity.
- Won't runNew Holland L320 (standard flow)20.6 GPM is well below the 50 GPM minimum. 3046 PSI is within the head's pressure rating. 67 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2000 lb rated operating capacity.
- Won't runNew Holland L321 (standard flow)24.2 GPM is well below the 50 GPM minimum. 3046 PSI is within the head's pressure rating. 74 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2100 lb rated operating capacity.
- Won't runNew Holland L328 (standard flow)24.2 GPM is well below the 50 GPM minimum. 3046 PSI is within the head's pressure rating. 74 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2800 lb rated operating capacity.
- Won't runNew Holland L334 (standard flow)24.2 GPM is well below the 50 GPM minimum. 3450 PSI is within the head's pressure rating. 90 HP is well below the 125 HP minimum.
- Won't runTakeuchi TL10V2 (standard flow)18.8 GPM is well below the 50 GPM minimum. 3191 PSI is within the head's pressure rating. 74.3 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2525 lb rated operating capacity.
- Won't runTakeuchi TL11R3 (standard flow)23.1 GPM is well below the 50 GPM minimum. 3481 PSI is within the head's pressure rating. 107.3 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2735 lb rated operating capacity.
- Won't runTakeuchi TL12R2 (standard flow)23.3 GPM is well below the 50 GPM minimum. 3481 PSI is within the head's pressure rating. 111.3 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2975 lb rated operating capacity.
- Won't runTakeuchi TL12V2 (standard flow)23.2 GPM is well below the 50 GPM minimum. 3481 PSI is within the head's pressure rating. 111.3 HP is well below the 125 HP minimum.
- Won't runTakeuchi TL6R (standard flow)17.7 GPM is well below the 50 GPM minimum. 2988 PSI is within the head's pressure rating. 65.2 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 1840 lb rated operating capacity.
- Won't runTakeuchi TL8R2 (standard flow)20 GPM is well below the 50 GPM minimum. 3046 PSI is within the head's pressure rating. 74.3 HP is well below the 125 HP minimum. Head weighs 3300 lb, more than the 2115 lb rated operating capacity.