Cat HM112 Mulcher: specs & which machines can run it
Forestry Mulcher rated for 16–18 GPM. Good fit on 3 of the 64 loaders we track.
Specs
- Type
- Forestry Mulchers
- Flow class
- standard
- Min flow
- 16 GPM
- Max flow
- 18 GPM
- Min pressure
- 2900 PSI
- Max pressure
- 3336 PSI
- Min HP
- not published
- Max HP
- not published
- Width
- 49 in
- Weight
- 1682 lb
Maker-listed compatible machines: 216B3, 226B3, 226D3, 232D3, 239D3, 249D3
Source: https://www.petersoncat.com/sites/default/files/products/documents/-113626.pdf (official doc (Cat AEHQ8447) hosted by dealer Peterson Cat)
Placeholder · affiliate link
Affiliate / “get a quote” link for Cat HM112 Mulcher goes here. No affiliate program is connected yet.
Placeholder · featured partner slot
Featured maker / dealer slot — Cat dealers. Reserved for a future paid placement. No partner has been signed. This box is intentionally empty.
Verify with your dealer. Results come from published specs and our matching rules. They are not a guarantee. Coupler type, case-drain line, electrical connectors, auxiliary options, relief settings and model year all matter. Confirm with the dealer and the attachment maker before you buy or run anything.
Machines that can run the Cat HM112 Mulcher
3 good fit20 marginal41 won't run
- Good fit
- Good fitKubota SVL65-2 (standard flow)17.4 GPM is inside the 16-18 GPM range. 3263 PSI is within the head's pressure rating.
- Good fitTakeuchi TL6R (standard flow) · details17.7 GPM is inside the 16-18 GPM range. 2988 PSI is within the head's pressure rating.
- MarginalASV RT-135 (standard flow)20 GPM is above the 18 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3300 PSI is within the head's pressure rating.
- MarginalASV RT-135 Forestry (standard flow)20 GPM is above the 18 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3300 PSI is within the head's pressure rating.
- MarginalBobcat S450 (standard flow)16.7 GPM is inside the 16-18 GPM range. 3300 PSI is within the head's pressure rating. Head weighs 1682 lb, more than the 1370 lb rated operating capacity.
- MarginalBobcat S590 (standard flow)17.1 GPM is inside the 16-18 GPM range. Machine relief 3500 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- MarginalBobcat S64-2 (standard flow)17.6 GPM is inside the 16-18 GPM range. Machine relief 3500 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- MarginalBobcat S66-2 (standard flow)17.6 GPM is inside the 16-18 GPM range. Machine relief 3500 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- MarginalBobcat T450 (standard flow)16.7 GPM is inside the 16-18 GPM range. 3300 PSI is within the head's pressure rating. Head weighs 1682 lb, more than the 1490 lb rated operating capacity.
- MarginalBobcat T595 (standard flow)17.1 GPM is inside the 16-18 GPM range. Machine relief 3500 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- Marginal
- MarginalBobcat T64-2 (standard flow)17.6 GPM is inside the 16-18 GPM range. Machine relief 3500 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- MarginalBobcat T66-2 (standard flow)17.6 GPM is inside the 16-18 GPM range. Machine relief 3500 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- MarginalCat 239D3 (standard flow)18 GPM is inside the 16-18 GPM range. 3336 PSI is within the head's pressure rating. Head weighs 1682 lb, more than the 1530 lb rated operating capacity.
- MarginalCat 259D3 (standard flow)20 GPM is above the 18 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3336 PSI is within the head's pressure rating.
- MarginalJohn Deere 317G (standard flow)17 GPM is inside the 16-18 GPM range. Machine relief 3450 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- MarginalKubota SVL75-3 (standard flow)19.2 GPM is above the 18 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3185 PSI is within the head's pressure rating.
- MarginalNew Holland L316 (standard flow)18.4 GPM is above the 18 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3046 PSI is within the head's pressure rating. Head weighs 1682 lb, more than the 1600 lb rated operating capacity.
- MarginalNew Holland L318 (standard flow)20.6 GPM is above the 18 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3046 PSI is within the head's pressure rating.
- MarginalNew Holland L320 (standard flow)20.6 GPM is above the 18 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3046 PSI is within the head's pressure rating.
- MarginalTakeuchi TL10V2 (standard flow)18.8 GPM is above the 18 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3191 PSI is within the head's pressure rating.
- MarginalTakeuchi TL8R2 (standard flow)20 GPM is above the 18 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3046 PSI is within the head's pressure rating.
- Won't runASV RT-50 (standard flow)13.3 GPM is well below the 16 GPM minimum. 3000 PSI is within the head's pressure rating. Head weighs 1682 lb, more than the 1400 lb rated operating capacity.
- Won't runASV RT-65 (standard flow)21.4 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. Machine relief 3771 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- Won't runASV RT-75 (standard flow)22.6 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. 3300 PSI is within the head's pressure rating.
- Won't runASV VT-100 (standard flow)23 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. Machine relief 3481 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- Won't runASV VT-75 (standard flow)21.4 GPM is far above the 18 GPM maximum - wrong motor size for this circuit.
- Won't runASV VT-80 (standard flow)24.7 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. Machine relief 3771 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- Won't runBobcat S650 (standard flow)23 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. Machine relief 3500 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- Won't runBobcat S70 (standard flow)8.9 GPM is well below the 16 GPM minimum. 2000 PSI is below the 2900 PSI the head is rated for - less torque. Head weighs 1682 lb, more than the 760 lb rated operating capacity.
- Won't runBobcat S76-2 (standard flow)23.3 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. Machine relief 3500 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- Won't runBobcat S770 (standard flow)23 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. Machine relief 3500 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- Won't runBobcat S86-2 (standard flow)23 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. Machine relief 4061 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- Won't runBobcat T650 (standard flow)23 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. Machine relief 3500 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- Won't runBobcat T76-2 (standard flow)23.3 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. Machine relief 3500 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- Won't runBobcat T770 (standard flow)23 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. Machine relief 3500 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- Won't runBobcat T86-2 (standard flow)23 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. Machine relief 4061 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- Won't runCASE TR270B (standard flow)24.2 GPM is far above the 18 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TR310B (standard flow)24.2 GPM is far above the 18 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TR340B (standard flow)24.2 GPM is far above the 18 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TV370B (standard flow)24.2 GPM is far above the 18 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TV450B (standard flow)24.2 GPM is far above the 18 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TV620B (standard flow)24.2 GPM is far above the 18 GPM maximum - wrong motor size for this circuit.
- Won't runCat 279D3 (standard flow)23 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. 3336 PSI is within the head's pressure rating.
- Won't runCat 289D3 (standard flow)23 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. 3336 PSI is within the head's pressure rating.
- Won't runCat 299D3 (standard flow)23 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. 3335 PSI is within the head's pressure rating.
- Won't runCat 299D3 XE (standard flow)23 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. 3335 PSI is within the head's pressure rating.
- Won't runJohn Deere 325G (standard flow)21 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. Machine relief 3450 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- Won't runJohn Deere 331G (standard flow)23.5 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. Machine relief 3450 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- Won't runJohn Deere 333G (standard flow)25 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. Machine relief 3450 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- Won't runKubota SVL97-2 (standard flow)23.1 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. Machine relief 3553 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- Won't runNew Holland C327 (standard flow)24.2 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. 3046 PSI is within the head's pressure rating.
- Won't runNew Holland C332 (standard flow)24.2 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. 3046 PSI is within the head's pressure rating.
- Won't runNew Holland C334 (standard flow)24.2 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. 3046 PSI is within the head's pressure rating.
- Won't runNew Holland C337 (standard flow)24.2 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. 3046 PSI is within the head's pressure rating.
- Won't runNew Holland C345 (standard flow)24.2 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. Machine relief 3450 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- Won't runNew Holland C362 (standard flow)24.2 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. Machine relief 3450 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- Won't runNew Holland L321 (standard flow)24.2 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. 3046 PSI is within the head's pressure rating.
- Won't runNew Holland L328 (standard flow)24.2 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. 3046 PSI is within the head's pressure rating.
- Won't runNew Holland L334 (standard flow)24.2 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. Machine relief 3450 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- Won't runTakeuchi TL11R3 (standard flow)23.1 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. Machine relief 3481 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- Won't runTakeuchi TL12R2 (standard flow)23.3 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. Machine relief 3481 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.
- Won't runTakeuchi TL12V2 (standard flow)23.2 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. Machine relief 3481 PSI exceeds the head's 3336 PSI max - confirm relief setting with dealer.