Blue Diamond Cold Planer Extreme Duty Series 2, 14 in: specs & which machines can run it
Cold Planer rated for 12–21 GPM. Good fit on 24 of the 64 loaders we track.
Specs
- Type
- Cold Planers
- Flow class
- standard
- Min flow
- 12 GPM
- Max flow
- 21 GPM
- Min pressure
- not published
- Max pressure
- 3625 PSI
- Min HP
- not published
- Max HP
- not published
- Width
- 14 in
- Weight
- 1350 lb
Cutting depth 4.3 in.
Source: https://www.bluediamondattachments.com/attachments/cold-planer (official)
Placeholder · affiliate link
Affiliate / “get a quote” link for Blue Diamond Cold Planer Extreme Duty Series 2, 14 in goes here. No affiliate program is connected yet.
Placeholder · featured partner slot
Featured maker / dealer slot — Blue Diamond dealers. Reserved for a future paid placement. No partner has been signed. This box is intentionally empty.
Verify with your dealer. Results come from published specs and our matching rules. They are not a guarantee. Coupler type, case-drain line, electrical connectors, auxiliary options, relief settings and model year all matter. Confirm with the dealer and the attachment maker before you buy or run anything.
Machines that can run the Blue Diamond Cold Planer Extreme Duty Series 2, 14 in
24 good fit22 marginal18 won't run
- Good fitASV RT-135 (standard flow)20 GPM is inside the 12-21 GPM range. 3300 PSI is within the head's pressure rating.
- Good fitASV RT-135 Forestry (standard flow)20 GPM is inside the 12-21 GPM range. 3300 PSI is within the head's pressure rating.
- Good fitASV RT-50 (standard flow)13.3 GPM is inside the 12-21 GPM range. 3000 PSI is within the head's pressure rating.
- Good fitBobcat S450 (standard flow)16.7 GPM is inside the 12-21 GPM range. 3300 PSI is within the head's pressure rating.
- Good fitBobcat S590 (standard flow)17.1 GPM is inside the 12-21 GPM range. 3500 PSI is within the head's pressure rating.
- Good fitBobcat S64-2 (standard flow)17.6 GPM is inside the 12-21 GPM range. 3500 PSI is within the head's pressure rating.
- Good fitBobcat S66-2 (standard flow)17.6 GPM is inside the 12-21 GPM range. 3500 PSI is within the head's pressure rating.
- Good fitBobcat T450 (standard flow)16.7 GPM is inside the 12-21 GPM range. 3300 PSI is within the head's pressure rating.
- Good fitBobcat T595 (standard flow)17.1 GPM is inside the 12-21 GPM range. 3500 PSI is within the head's pressure rating.
- Good fitBobcat T64-2 (standard flow)17.6 GPM is inside the 12-21 GPM range. 3500 PSI is within the head's pressure rating.
- Good fitBobcat T66-2 (standard flow)17.6 GPM is inside the 12-21 GPM range. 3500 PSI is within the head's pressure rating.
- Good fitCat 239D3 (standard flow)18 GPM is inside the 12-21 GPM range. 3336 PSI is within the head's pressure rating.
- Good fitCat 249D3 (standard flow)18 GPM is inside the 12-21 GPM range. 3336 PSI is within the head's pressure rating.
- Good fitCat 259D3 (standard flow)20 GPM is inside the 12-21 GPM range. 3336 PSI is within the head's pressure rating.
- Good fitJohn Deere 317G (standard flow)17 GPM is inside the 12-21 GPM range. 3450 PSI is within the head's pressure rating.
- Good fitJohn Deere 325G (standard flow)21 GPM is inside the 12-21 GPM range. 3450 PSI is within the head's pressure rating.
- Good fitKubota SVL65-2 (standard flow)17.4 GPM is inside the 12-21 GPM range. 3263 PSI is within the head's pressure rating.
- Good fitKubota SVL75-3 (standard flow)19.2 GPM is inside the 12-21 GPM range. 3185 PSI is within the head's pressure rating.
- Good fitNew Holland L316 (standard flow)18.4 GPM is inside the 12-21 GPM range. 3046 PSI is within the head's pressure rating.
- Good fitNew Holland L318 (standard flow)20.6 GPM is inside the 12-21 GPM range. 3046 PSI is within the head's pressure rating.
- Good fitNew Holland L320 (standard flow)20.6 GPM is inside the 12-21 GPM range. 3046 PSI is within the head's pressure rating.
- Good fitTakeuchi TL10V2 (standard flow)18.8 GPM is inside the 12-21 GPM range. 3191 PSI is within the head's pressure rating.
- Good fitTakeuchi TL6R (standard flow)17.7 GPM is inside the 12-21 GPM range. 2988 PSI is within the head's pressure rating.
- Good fitTakeuchi TL8R2 (standard flow)20 GPM is inside the 12-21 GPM range. 3046 PSI is within the head's pressure rating.
- MarginalASV RT-65 (standard flow)21.4 GPM is above the 21 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. Machine relief 3771 PSI exceeds the head's 3625 PSI max - confirm relief setting with dealer.
- MarginalASV RT-75 (standard flow)22.6 GPM is above the 21 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3300 PSI is within the head's pressure rating.
- MarginalASV VT-100 (standard flow)23 GPM is above the 21 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3481 PSI is within the head's pressure rating.
- MarginalASV VT-75 (standard flow)21.4 GPM is above the 21 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed.
- MarginalBobcat S650 (standard flow)23 GPM is above the 21 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3500 PSI is within the head's pressure rating.
- MarginalBobcat S76-2 (standard flow)23.3 GPM is above the 21 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3500 PSI is within the head's pressure rating.
- MarginalBobcat S770 (standard flow)23 GPM is above the 21 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3500 PSI is within the head's pressure rating.
- MarginalBobcat S86-2 (standard flow)23 GPM is above the 21 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. Machine relief 4061 PSI exceeds the head's 3625 PSI max - confirm relief setting with dealer.
- Marginal
- MarginalBobcat T650 (standard flow)23 GPM is above the 21 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3500 PSI is within the head's pressure rating.
- MarginalBobcat T76-2 (standard flow)23.3 GPM is above the 21 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3500 PSI is within the head's pressure rating.
- MarginalBobcat T770 (standard flow)23 GPM is above the 21 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3500 PSI is within the head's pressure rating.
- MarginalBobcat T86-2 (standard flow)23 GPM is above the 21 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. Machine relief 4061 PSI exceeds the head's 3625 PSI max - confirm relief setting with dealer.
- MarginalCat 279D3 (standard flow)23 GPM is above the 21 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3336 PSI is within the head's pressure rating.
- MarginalCat 289D3 (standard flow)23 GPM is above the 21 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3336 PSI is within the head's pressure rating.
- MarginalCat 299D3 (standard flow)23 GPM is above the 21 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3335 PSI is within the head's pressure rating.
- MarginalCat 299D3 XE (standard flow)23 GPM is above the 21 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3335 PSI is within the head's pressure rating.
- MarginalJohn Deere 331G (standard flow)23.5 GPM is above the 21 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3450 PSI is within the head's pressure rating.
- MarginalKubota SVL97-2 (standard flow)23.1 GPM is above the 21 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3553 PSI is within the head's pressure rating.
- MarginalTakeuchi TL11R3 (standard flow)23.1 GPM is above the 21 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3481 PSI is within the head's pressure rating.
- MarginalTakeuchi TL12R2 (standard flow)23.3 GPM is above the 21 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3481 PSI is within the head's pressure rating.
- MarginalTakeuchi TL12V2 (standard flow)23.2 GPM is above the 21 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3481 PSI is within the head's pressure rating.
- Won't runASV VT-80 (standard flow)24.7 GPM is far above the 21 GPM maximum - wrong motor size for this circuit. Machine relief 3771 PSI exceeds the head's 3625 PSI max - confirm relief setting with dealer.
- Won't runBobcat S70 (standard flow)8.9 GPM is well below the 12 GPM minimum. 2000 PSI is within the head's pressure rating. Head weighs 1350 lb, more than the 760 lb rated operating capacity.
- Won't runCASE TR270B (standard flow)24.2 GPM is far above the 21 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TR310B (standard flow)24.2 GPM is far above the 21 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TR340B (standard flow)24.2 GPM is far above the 21 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TV370B (standard flow)24.2 GPM is far above the 21 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TV450B (standard flow)24.2 GPM is far above the 21 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TV620B (standard flow)24.2 GPM is far above the 21 GPM maximum - wrong motor size for this circuit.
- Won't runJohn Deere 333G (standard flow)25 GPM is far above the 21 GPM maximum - wrong motor size for this circuit. 3450 PSI is within the head's pressure rating.
- Won't runNew Holland C327 (standard flow)24.2 GPM is far above the 21 GPM maximum - wrong motor size for this circuit. 3046 PSI is within the head's pressure rating.
- Won't runNew Holland C332 (standard flow)24.2 GPM is far above the 21 GPM maximum - wrong motor size for this circuit. 3046 PSI is within the head's pressure rating.
- Won't runNew Holland C334 (standard flow)24.2 GPM is far above the 21 GPM maximum - wrong motor size for this circuit. 3046 PSI is within the head's pressure rating.
- Won't runNew Holland C337 (standard flow)24.2 GPM is far above the 21 GPM maximum - wrong motor size for this circuit. 3046 PSI is within the head's pressure rating.
- Won't runNew Holland C345 (standard flow)24.2 GPM is far above the 21 GPM maximum - wrong motor size for this circuit. 3450 PSI is within the head's pressure rating.
- Won't runNew Holland C362 (standard flow)24.2 GPM is far above the 21 GPM maximum - wrong motor size for this circuit. 3450 PSI is within the head's pressure rating.
- Won't runNew Holland L321 (standard flow)24.2 GPM is far above the 21 GPM maximum - wrong motor size for this circuit. 3046 PSI is within the head's pressure rating.
- Won't runNew Holland L328 (standard flow)24.2 GPM is far above the 21 GPM maximum - wrong motor size for this circuit. 3046 PSI is within the head's pressure rating.
- Won't runNew Holland L334 (standard flow)24.2 GPM is far above the 21 GPM maximum - wrong motor size for this circuit. 3450 PSI is within the head's pressure rating.